{"product_id":"robertshaw-millivolt-natural-gas-valve-replacement-for-imperial-pitco-fryers","title":"\"Robertshaw Millivolt Natural Gas Valve Replacement for Imperial, Pitco fryers","description":"\u003ch2\u003eRobertshaw U7000 Unitrol Millivolt Natural Gas Valve – BMVR Replacement\u003c\/h2\u003e\n\u003cp\u003eReplace an older or faulty BMVR gas control with this \u003cstrong\u003eRobertshaw U7000 Unitrol millivolt gas valve\u003c\/strong\u003e. Designed for \u003cstrong\u003eNatural Gas appliances\u003c\/strong\u003e, this valve is commonly used in compatible commercial fryers and other gas-powered catering equipment.\u003c\/p\u003e\n\u003cp\u003eIt provides a modern replacement solution for older Robertshaw BMVR-style valves and operates using a thermopile-generated millivolt signal, without requiring a standard mains electrical supply.\u003c\/p\u003e\n\u003ch3\u003eMain Product Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eSuitable replacement for older Robertshaw BMVR gas valves\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDesigned exclusively for Natural Gas applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMillivolt-operated gas control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompatible with selected Imperial and Pitco fryers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupplied with an adaptor nut for different pipe connection sizes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSuitable for commercial catering equipment repairs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReliable Unitrol-style gas control design\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eRobertshaw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eValve Series\u003c\/td\u003e\n\u003ctd\u003eU7000 Unitrol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eValve Type\u003c\/td\u003e\n\u003ctd\u003eMillivolt gas control valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Type\u003c\/td\u003e\n\u003ctd\u003eNatural Gas only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Range\u003c\/td\u003e\n\u003ctd\u003e250–750 millivolts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Inlet Pressure\u003c\/td\u003e\n\u003ctd\u003e1\/2 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Rating\u003c\/td\u003e\n\u003ctd\u003e4\" WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePipework Compatibility\u003c\/td\u003e\n\u003ctd\u003e1\/2\" or 3\/4\" using supplied conversion nut\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCondition\u003c\/td\u003e\n\u003ctd\u003eBrand new\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatible Applications\u003c\/h3\u003e\n\u003cp\u003eThis valve may be suitable for selected:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eImperial commercial fryers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePitco gas fryers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCommercial cooking appliances\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMillivolt-controlled gas equipment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAppliances previously fitted with a compatible BMVR valve\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompatibility can vary between appliance models and production versions. The equipment make alone does not guarantee that the valve will fit.\u003c\/p\u003e\n\u003ch3\u003eMillivolt Operation\u003c\/h3\u003e\n\u003cp\u003eThe valve is designed to operate from a millivolt power source, usually generated by a compatible thermopile or pilot generator. Its stated operating range is approximately \u003cstrong\u003e250–750mV\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eBefore ordering, ensure that the appliance uses the correct millivolt control system and that the existing thermopile is operating correctly.\u003c\/p\u003e\n\u003ch3\u003eSupplied Adaptor\u003c\/h3\u003e\n\u003cp\u003eA conversion thread nut is included, allowing the valve to be connected to compatible \u003cstrong\u003e1\/2-inch or 3\/4-inch pipework\u003c\/strong\u003e, depending on the appliance arrangement.\u003c\/p\u003e\n\u003cp\u003eAdditional fittings, thermopiles, pilot assemblies and control components are not included unless specifically shown.\u003c\/p\u003e\n\u003ch3\u003ePackage Contents\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e1 × Robertshaw U7000 Unitrol Natural Gas valve\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 × Conversion thread nut\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNatural Gas Version Only\u003c\/h3\u003e\n\u003cp\u003eThis listing is strictly for the \u003cstrong\u003eNatural Gas valve\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIt is not suitable for LPG or propane appliances unless conversion is specifically authorised by the appliance and valve manufacturers and completed using approved components. Please select the separate LPG listing when an LPG valve is required.\u003c\/p\u003e\n\u003ch3\u003eConfirm Compatibility Before Ordering\u003c\/h3\u003e\n\u003cp\u003ePlease compare the following with your existing valve:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eGas type\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eValve model and reference numbers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMillivolt operating range\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInlet and outlet connection sizes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePressure rating\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePipe orientation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMounting arrangement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAppliance make and model\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProfessional Installation\u003c\/h3\u003e\n\u003cp\u003eThis gas valve must be installed, adjusted and tested by a suitably qualified Gas Safe registered engineer. Following installation, the appliance should be checked for gas leaks, correct operating pressure, pilot safety operation and safe combustion.\u003c\/p\u003e\n\u003ch3\u003eDelivery and Returns\u003c\/h3\u003e\n\u003cp\u003eOrders are packaged securely and dispatched promptly.\u003c\/p\u003e\n\u003cp\u003eReturns are accepted within 30 days of delivery. The buyer is responsible for return postage, and returned products must be unused and in their original condition.\u003c\/p\u003e","brand":"Unique Food Machinery","offers":[{"title":"Default Title","offer_id":53257004777800,"sku":null,"price":99.79,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0835\/6207\/0344\/files\/s-l1600_1_61d4501c-e6bf-454c-b425-333fa5648143.webp?v=1781023196","url":"https:\/\/uniquefoodmachinery.co.uk\/products\/robertshaw-millivolt-natural-gas-valve-replacement-for-imperial-pitco-fryers","provider":"Unique Food Machinery","version":"1.0","type":"link"}